亚洲亚洲人成综合网络-国模欢欢炮交啪啪150-国产精品亚韩精品无码a在线-被群cao的合不拢腿h纯肉视频

AC source power & DC source power manufacturing factory
Linear Standard AC Power Source APA1000L Series

Linear Standard AC Power Source APA1000L Series

Product parameter 
? Input voltage range: Single phase 195~245V     
Three phase 340V~420V
? Input frequency range: 50/60Hz±5%
? Output voltage range: Single phase 0~300V (0~600V Match)   
Three phase 0~520V (0~1040V Match)
? Output frequency range: 45~500Hz
? Waveform Distortion≤0.3%    Load Regulation≤0.5%    Frequency stability≤0.01%
? Three-phase phase angle can be adjusted (0-120 degrees), each phase in use can independently adjust voltage and frequency, and independently display voltage and frequency linear climb and drop editing test function, can do voltage and frequency gradient and interrupt test, and has independent compensation function of impedance, can simulate various test and test power supply of power grid.

Online quote

Product details

High Performance 
? Low Distortion Interference, Complete Input/Output Isolation
? The maximum single-phase capacity can reach 15KVA and the three-phase power supply can reach 45KVA.
? Remote voltage feedback function to ensure the consistency of test point voltage value and setting value
? Voltage and current measurements are based on high precision ADC AC sampling and digital real value calculation.
? A single chip computer (D/A circuit) is used to collect voltage and current waveform data directly. contains RS232 or RS485 interface, communicate with computer.
? Built-in soft start device can easily start motor, compressor and other high starting current load
? The central processing unit is used to control the opening and closing of logic circuits. The one-to-one driving method is beneficial to disperse heat dissipation of power components and redundant design in structure.
? Inspection of temperature and humidity in the machine, intelligent ventilation and are faction in wet weather to ensure the normal use of power supply

Humanized design
? LCD Display parameters: voltage, current, power, power factor, frequency, peak current and time
? LED Displaying voltage, current, frequency, power ( power factor)
? A group of test groups can execute 35 test points (different voltage0~300V, frequency45~500Hz, time 0.1S-999.9H settings), and can do continuous cycle (0~99999999 times) testing. 
? Power supply multi-point real-time sensor monitoring, running normal code and fault code screen display, fully control the power supply status.
? The parameter calibration is accomplished by open software, and different from other power sources, the potentiometer and adjustable resistance are also adjusted in the circuit.
? Wide range of voltage and frequency regulation, digital key input, independent display of three-phase voltage and line voltage
? Digital password lock, test data security and prevent important test data from being modified by misoperation

APA1000L Single phase series

Model 1000L 1001L 1002L 1003L 1005L 1010L 1015L
Output Capacity 500VA 1KVA 2KVA 3KVA 5KVA 10KVA 15KVA
Input Power 1?2W+G 110V/220V±10%  220V±10% 50/60Hz±5%
Output Frequency 50Hz/ 60Hz/ 45~500Hz
Frequency stability 0.01%
Output Voltage 0~150V/0~300V(AUTO)
Output current 4.2/2.1 8.4/4.2 16.8/8.4 25/12.5 42/21 84/42 126/63
Load Regulation ≤0.5%
Waveform Distortion ≤0.3%
Meter Display LED/LCD Display Voltage, Current, Frequency and Power (Peak Current Time Power Factor)
Protective Device Overload, Overcurrent, Temperature, Short Circuit, Undervoltage Protection and Alarm
Working condition ambient temperature 0~40°C   relative humidity10~90%

APA1000LS Three phase series

Model 1006LS 1010LS 1015LS 1020LS 1030LS 1045LS
Output Capacity 6KVA 10KVA 15KVA 20KVA 30KVA 45KVA
Input Power 1?2W+G 220V±10% 3?4W+G 220V/380V±10%  50/60Hz±5%
Output Frequency 50Hz/ 60Hz/ 45~500Hz
Frequency stability 0.01%
Output Voltage 相電壓 0~150V/0~300V (AUTO)
Output current 16.8/8.4 27.5/13.75 42/21 55.6/27.8 84/42 126/63
Load Regulation ≤0.5%
Waveform Distortion ≤0.3%
Meter Display LED/LCD Display Voltage, Current, Frequency and Power (Peak Current Time Power Factor)
Protective Device Protection and alarm of short circuit, short voltage and short phase with overload, over current and over temperature
Working condition ambient temperature 0~40°C   relative humidity10~90%

Online service
Service Hotline
86-769-89616802
86-13602353727

ADMIRE POWER