High Performance
? Digital Voltmeter and Current Resolution 4 Bit Half Display (Optional), AC Voltmeter and
current Real Value Measurement
? DDS waveform generator with frequency resolution of 6.5 bits
? Maximum current up to 30000 A (provide linear and switching power supply, fully meet the
requirements of different situations. Linear structure can be used in high EMI
requirements,high dynamic range. High linearity: Switching structure has the advantages
of high efficiency,high dynamic range and small size.
? Current can be multistage (e.g. 2mA, 20mA, 200mA, 2A, 20A, 200A)
? LED/LCD Display Voltage, Current
? Maximum pressure drop can be customized according to demand
? Modular structure, durable and reliable
? Low temperature coefficient: 300 ppm
? Protection and alarm function: over-temperature, open circuit, over-high and over-low
working voltage
Suitable place
? AC Current Sensor (CT), Diverter Correction, Hall Current Sensor Check
? Coupler calibration, current bar calibration, power meter calibration, power meter calibration, disk meter calibration, digital meter calibration
? Overlapping current generator and material test
Output phase | 1?2W+G/ 3?4W+G |
---|---|
Output Current | Customized according to demand, the maximum accuracy of 30000 A is less than 1%. |
Output Current Gear | Customized according to demand |
Current Temperature Coefficient | 300P.P.M/℃ |
Output Frequency |
Customized frequency resolution (e.g. 45.00-65.00 Hz, 400 Hz, 1KHz...) according to requirements: 0.1 Hz; accuracy: 0.01% stability: 0.01 Hz temperature effect:50ppm/℃ |
Sinusoidal Wave Generator | DDS Direct Frequency Synthesizer |
Sinusoidal Waveform Coefficient | 1.414(Resistive load) |
Max pressure drop | Customized according to demand |
DC bias voltage | Lower than±1mV |
Open circuit voltage | Customized according to demand(Max15V) |
Output Voltage Temperature Effect | ±0.2%/℃ |
Output total harmonics |
0.3%(50Hz 10~100% Full scale current;Resister Load;PF=1,THD-R measurement) (80KHz BW) |
Setting accuracy | Current ±0.1% ±2c(50/60Hz 0.1%/100Hz) Frequency±0.05% ±1c(50/60Hz 0.05%/100Hz) |
Measurement accuracy(RMS) | Voltage ±(0.5% Range+0.5%Read)±2C(at50Hz)Current ±(0.5% Range+0.5%Read)±5C(at50Hz) |
Power Stability Rate | ±0.2%(ACV±10%;THD≦2%;Frequency±5%)(at 80%Full scale;Load=0~50%;PF=1) |
Load Stability Rate | ±0.5%(10~100% Full scale Current) |
Inductive load | <2mH (at sin wave 50Hz) |
Heat engine time | 30Min |
Protection function | Output open circuit/Working voltage is too high or too low/Input power supply voltage is too high or too low(±15%)/Overtemperature protection and alarm |
Operating environment | temperature 0~+45℃ humidity 10~90% |
Insulation resistance | 10Mohm 500DC(line input terminal to casing) |
Selection Specification (APA3000 Series)
0~30A | 0~50A | 0~100A | 0~200A | 0~400A | 0~600A | 0-1000A | |
---|---|---|---|---|---|---|---|
0~20V | 3020-30A | 3020-50A | 3020-100A | 3020-200A | 3020-400A | 3020-600A | 3020-1000A |
0~50V | 3050-30A | 3050-50A | 3050-100A | 3050-200A | 3050-400A | 3050-600A | 3050-1000A |
0~100V | 3100-30A | 3100-50A | 3100-100A | 3100-200A | 3100-400A | 3100-600A | 3100-1000A |
0~200V | 3200-30A | 3200-50A | 3200-100A | 3200-200A | 3200-400A | 3200-600A | 3200-1000A |
0~300V | 3300-30A | 3300-50A | 3300-100A | 3300-200A | 3300-400A | 3300-600A | 3300-1000A |
0~400V | 3400-30A | 3400-50A | 3400-100A | 3400-200A | 3400-400A | 3400-600A | 3400-1000A |
0~500V | 3500-30A | 3500-50A | 3500-100A | 3500-200A | 3500-400A | 3500-600A | 3500-1000A |
0~600V | 3600-30A | 3600-50A | 3600-100A | 3600-200A | 3600-400A | 3600-600A | 3600-1000A |